Aurora Telecom: Fibre Sensing and Route Diversity Can Prevent Network Outages
By Colin Ryan 334 views
Aurora Telecom’s Phelim Dolan says route diversity, infrastructure protection and fibre sensing can help spot threats before connectivity is disrupted.

For network operators, resilience starts before an outage: with routes, power systems and physical protection designed to limit the chance that one fault interrupts service. Phelim Dolan, network manager at Aurora Telecom, says that prevention is increasingly central to business continuity as organisations depend on connectivity for cloud services, payments, remote work, healthcare and customer operations.

A failure can mean more than a lost connection. Dolan points to operational disruption, financial losses, reduced customer confidence and reputational damage. For services that depend on continuous availability, even a brief interruption can have wider effects. The practical lesson for IT leaders is to assess how connectivity is engineered and protected, alongside price and bandwidth.

Design against single points of failure
Aurora Telecom, a business unit of Gas Networks Ireland, operates a backhaul dark fibre network linking major cities, data centres, subsea cable landing locations and critical infrastructure around Ireland. Dolan says the mission critical services carried over that infrastructure make resilience a design priority, from physical protection and maintenance to real time monitoring and newer tools such as fibre sensing.

Resilience, in his view, means reducing the likelihood of failure as well as restoring service when a fault occurs. That calls for sound network design, diverse routes, proactive monitoring and protection of physical assets. A network with weak design choices can conceal vulnerabilities until an incident exposes them.

Examples include insufficient route diversity, too many network splices, inadequate power redundancy and excessive dependence on one supplier. Any of these can leave a service exposed to a failure that affects applications, data, communications or customer facing systems. Financial services, cloud computing, healthcare and public services may be particularly sensitive to interruptions, Dolan says.

For Aurora’s network planning, route selection includes looking for shared failure points and providing alternative paths where possible. Physical availability also depends on the quality of the fibre, secure co location facilities, backup power, environmental controls and ongoing monitoring. These measures work together: a second route offers limited protection if it shares a vulnerable site or lacks power when needed.

That makes resilience a question of design choices across the full service path, rather than a single backup component. Network buyers can ask providers how routes are diversified, what power arrangements support key facilities, and how physical infrastructure is monitored and maintained. The answers help reveal whether redundancy is built into the service or assumed after a fault.

Fibre as an early warning system
Dolan identifies fibre sensing as a developing way to protect critical infrastructure. Distributed acoustic sensing and distributed temperature sensing can analyse light that scatters back through fibre and identify changes from normal conditions. The cable can then serve both as a communications link and as a sensor along its route.

Depending on the system, those changes can indicate vibration, temperature shifts, ground movement or other environmental activity. The value is the chance to investigate a threat before it damages the cable or interrupts traffic. Dolan gives excavation near a fibre route as an example: sensing may detect nearby equipment early enough for operators to respond.

Conventional optical monitoring generally raises an alarm once the fibre is stretched, damaged or broken. That can help locate a problem, but the physical event has already happened and customer traffic may already be affected. Sensing activity ahead of damage could give operators time to intervene, though the benefit depends on detecting and assessing signals in time to act.
For teams responsible for connectivity, the distinction is operational: monitoring a break helps manage restoration, while detecting signs of a threat may create an opportunity to avoid the outage. Dolan describes that ability to respond before an event as a powerful addition to infrastructure protection.
Protect buried routes before excavation
Technology is only one part of prevention. Aurora also points to “dial before you dig” services, which allow contractors, utilities and developers to check for underground infrastructure before excavation. Consulting network records in advance can reduce the risk of accidentally cutting fibre or damaging other buried assets.
The step supports continuity for telecommunications and utility services, while helping works proceed with awareness of what lies below the site. Dolan frames advance asset checks as one of the most effective practical ways to improve resilience. For operators and organisations planning ground works, accurate records and early coordination can prevent a repair job from becoming a service incident.
Ireland’s role in international connectivity
Ireland’s position in global data networks raises the stakes for resilient backhaul, Dolan says. The country hosts hyperscale cloud providers, international technology companies, financial services organisations and transatlantic subsea cable systems. Large volumes of international traffic arrive in Ireland before travelling onward through European networks.
That makes dependable connectivity relevant beyond individual telecoms providers. Backhaul infrastructure supports business investment, economic activity, digital services and essential operations, while healthcare, financial networks, public services and communications platforms rely on it at home.
Dolan expects the need for protected fibre infrastructure to grow as demand rises for data, cloud services and applications powered by artificial intelligence. Network teams should therefore look closely at route diversity, power redundancy, physical asset protection and monitoring capability when reviewing connectivity plans. Prevention cannot remove every risk, but careful design and early warning can reduce how often a fault becomes an outage.